About DEXT MEDI
DEXT MEDI generates normalized data from raw data collected from medical devices, and securely transmits the generated data to
PACS or EMR servers within the hospital.
- • Data Automation : It prevents errors by directly collecting medical device data without manual entry..
- • Standards Compliance Support : Supports medical standard formats, including DICOM and HL7, CDA.
- • Flexible Integration: It can be integrated with medical examination equipment from various manufacturers.
Main Functions
It provides features prioritizing user convenience and system stability..
- • Various Data Collection Methods : Supports communication protocols tailored to device specifications, including TCP/IP, RS232C, and File Polling.
- • Automatic Transmission System : Automatically transmits collected data to a designated PACS server or EMR server (OpenAPI).
- • Customizable Settings : Allows for individual configuration by equipment manufacturer and model, enabling detailed management of information..
- • Stable Operating Environment : Supports Windows Service Mode for seamless background operation and logging and data backup functions.
Device Integration
Provides integration methods optimized for a wide range of medical devices.
| Device Integration |
Key Features |
Supported File / Data Formats |
| ECG Integration |
XSLT/XML-based data processing and
ECG image customization support
|
DICOM ECG, HL7 CDA, XML |
| RS232 Integration |
RAW data processing based on
device protocols and custom
image processing
|
Secondary Capture, HL7 CDA |
| File Integration |
Parsing of filenames/metadata
(CSV, TXT, etc.) and data
grouping
|
PNG, JPG, PDF, BMP ETC.. |
Workflow
The intuitive GUI allows even non-experts to manage the system with ease
- • Register & Configure : Register your device in the DEXT Medi program.
- • Model Selection : Select the manufacturer and model of the device you wish to integrate.
- • Integration Settings : Configure the port and data acquisition method tailored to the selected model.
- • Service Execution : Manage real-time data collection using the Start/Stop functions.
Application Areas
Easily collect diagnostic data from various medical departments and laboratories.
- • Applicable Departments : Health Screening Centers, Cardiology, Pulmonology, Ophthalmology, etc
- • Supported Device Examples :
- ECG / Stress Test : MAC2000, MAC3500, TC30, TC70, Quark CPET, CASE
- Arterial Sclerosis : VP-1000Plus
- Ophthalmic Equipment : CT-80, KR-8100, OCT, Optomap, CL-200
- Pulmonary Function Test : Vmax 22
- Hearing Test : GSI-68
System Requirements
- • Operating System : Windows 10 or later, Windows Server 2016 or later
- • Operation Mode : Selectable between Service Mode and Program Mode
- • Integration System : Integration with HIS, EMR, OCS, PACS (Mobile and kiosk support planned)